* create a ChType_Enum to go with SetChannelEnum * resolve build errors for ChType_Enum PR * fixing build errors for simulator and others for cmd_enums.c * added ChType_ReadOnlyEnum and assocaited enum selftests * ChType_Enum simulation and memory error corrections * ChType_Enum documentation updates * ChType_Enum autoexec example corrections --------- Co-authored-by: root <root@stonacek.nz> Co-authored-by: kcstonacek <kcstonacek@stonacek.nz>
106 lines
2.9 KiB
Batchfile
106 lines
2.9 KiB
Batchfile
// tuyaMCU store RAW data in /cm?cmnd=Dp must be turned off on this device..
|
|
setflag 46 0
|
|
|
|
ntp_setServer 132.163.97.4
|
|
ntp_timeZoneOfs 12:00
|
|
|
|
startDriver TuyaMCU
|
|
|
|
tuyaMcu_setBaudRate 115200
|
|
|
|
// always report paired
|
|
tuyaMcu_defWiFiState 4
|
|
|
|
// update states any time the temperature changes
|
|
addEventHandler OnChannelChange 27 tuyaMcu_sendQueryState
|
|
|
|
|
|
// 2 switch 1 relay bool - 121 device control must be 2 or 3 (remote mode)
|
|
setChannelType 21 Toggle
|
|
setChannelLabel 21 "Switch 1"
|
|
linkTuyaMCUOutputToChannel 2 bool 21
|
|
|
|
// 101 switch 2 relay bool - 121 device control must be 2 or 3 (remote mode)
|
|
setChannelType 22 Toggle
|
|
setChannelLabel 22 "Switch 2"
|
|
linkTuyaMCUOutputToChannel 101 bool 22
|
|
|
|
// 104 Switch 1 Automatic Mode bool
|
|
setChannelType 24 Toggle
|
|
setChannelLabel 24 "Switch 1 Auto Mode"
|
|
linkTuyaMCUOutputToChannel 104 bool 24
|
|
|
|
// 105 Switch 2 Automatic Mode bool
|
|
setChannelType 25 Toggle
|
|
setChannelLabel 25 "Switch 2 Auto Mode"
|
|
linkTuyaMCUOutputToChannel 105 bool 25
|
|
|
|
// 27 current temperature /10 - dpId 20 changes C/F
|
|
setChannelType 1 Temperature_div10
|
|
linkTuyaMCUOutputToChannel 27 val 1
|
|
|
|
// 46 current humidity
|
|
setChannelType 2 Humidity
|
|
linkTuyaMCUOutputToChannel 46 val 2
|
|
|
|
//102 online state enum; 0 online, 1 offline
|
|
setChannelType 3 ReadOnlyEnum
|
|
setChannelLabel 3 "Online State"
|
|
setChannelEnum 3 0:Online 1:Offline
|
|
linkTuyaMCUOutputToChannel 102 enum 3
|
|
|
|
// 118 event RO
|
|
setChannelType 4 ReadOnlyEnum
|
|
setChannelLabel 4 "Event Status"
|
|
SetChannelEnum 4 0:Normal "9:Buttons Locked" "10:Local Mode" "11:Remote Control" "12:Any Control"
|
|
linkTuyaMCUOutputToChannel 118 enum 4
|
|
|
|
// 121 device control mode enum; 0 local_lock, 1 MCU control, 2 OBK control, 3 MCU and Tuya control
|
|
setChannelType 5 Enum
|
|
setChannelLabel 5 "Device Control"
|
|
SetChannelEnum 5 "0:Buttons Locked" "1:Device Control" "2:Remote Control" "3:Any Control"
|
|
linkTuyaMCUOutputToChannel 121 enum 5
|
|
|
|
// 106 device Power-On Relay behaviour
|
|
setChannelType 6 Enum
|
|
setChannelLabel 6 "Power-on Behaviour"
|
|
SetChannelEnum 6 0:off 1:on 2:memory
|
|
linkTuyaMCUOutputToChannel 106 enum 6
|
|
|
|
// 107 Switch 1 Automatic Control Mode
|
|
setChannelType 7 Enum
|
|
setChannelLabel 7 "Switch 1 Control Mode"
|
|
setChannelEnum 7 0:Temp 1:Humidity
|
|
linkTuyaMCUOutputToChannel 107 enum 7
|
|
|
|
// 108 Switch 2 Automatic Control Mode
|
|
setChannelType 8 Enum
|
|
setChannelLabel 8 "Switch 2 Control Mode"
|
|
setChannelEnum 8 0:Temp 1:Humidity
|
|
linkTuyaMCUOutputToChannel 108 enum 8
|
|
|
|
// 22 Switch 1 Min Temp Set C -10-99
|
|
setChannelType 10 TextField
|
|
setChannelLabel 10 "Switch 1 Min C"
|
|
linkTuyaMCUOutputToChannel 22 val 10
|
|
|
|
// 110 Switch 1 Max Temp Set C -10-99
|
|
setChannelType 11 TextField
|
|
setChannelLabel 11 "Switch 1 Max C"
|
|
linkTuyaMCUOutputToChannel 110 val 11
|
|
|
|
// 113 Switch 2 Min Temp Set C -10-99
|
|
setChannelType 13 TextField
|
|
setChannelLabel 13 "Switch 2 Min C"
|
|
linkTuyaMCUOutputToChannel 113 val 13
|
|
|
|
// 115 Switch 2 Max Temp Set C -10-99
|
|
setChannelType 15 TextField
|
|
setChannelLabel 15 "Switch 2 Max C"
|
|
linkTuyaMCUOutputToChannel 115 val 15
|
|
|
|
// refresh tuyaMCU after definitions
|
|
tuyaMcu_sendQueryState
|
|
|
|
|